BTTVM - ROYCO 27A

Product Identification

Product ID:ROYCO 27A
MSDS Date:08/03/1993
FSC:9150
NIIN:01-307-4071
MSDS Number: BTTVM

Responsible Party
ROYAL LUBRICANTS COMPANY INC.
6 CAMPUS DR
PARSIPPANY, NJ 07054
US

Emergency Phone: 201-887-7411

Info Phone: 201-887-7410

Preparer: 710,057-1)

Cage: 07950

Contractor
ROYAL LUBRICANTS COMPANY INC.
518 EAST HANOVER, NJ 07936 US

Telephone: 973-887-7411/7410

Cage: 07950

Ingredients

SYNTHETIC ESTER, PER MSDS CAS# 1330-86-5.

Fraction By Weight: 70-80%


LITHIUM HYDROXYSTEARATE

CAS: 7620-77-1

Fraction By Weight: 10-20%


ANTIMONY DIALKYLDITHIOCARBAMATE

CAS: 15991-76-1

Fraction By Weight: 0-5%


ADDITIVES CONTAINING POLYISOBUTYLENE

Fraction By Weight: 0-5%


MINOR ADDITIVES

Fraction By Weight: <4%

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT) IS NOT AVAILABLE
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES/SKIN:MILDLY IRRIT.
INHAL:VAPORS GENERATED AT HIGH TEMPS WILL IRRIT NOSE/THROAT/UPPER
RESP TRACT. INGEST:PRODUCT GENERALLY CONSIDERED TO HAVE LOW ORDER
OF ACUTE ORAL TOXICITY. CHRONIC:PROLON G/REPEAT SKIN CONTACT MAY
CAUSE VARIOUSSKIN DISORDERS. HEALTH HAZ BASED ON COMPONENTS
INFORMATION.
Effects of Overexposure:EYE & SKIN AS WELL AS NOSE, THROAT & RESP TRACT
IRRITATION. SKIN DISORDERS:DERMATITIS, FOLLICULITIS OR OIL ACNE.
Medical Cond Aggravated by Exposure:BASED ON INFORMATION PERTAINING TO
THE LITHIUM HYDROXYSTEARATE INGREDIENT PREEXISTING RESPIRATORY
DISORDERS MAY BE AGGRAVATED BY EXPOSURE TO THIS PRODUCT.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR.DIFF IN BREATH GIVE OXY.GET MED
ATTN. INGEST:DON'T INDUCE VOMIT.NO TREATMENT NECESSARY UNLESS LG
AMTS INGESTED.GET MED ADVICE. EYE:FLUSH W/WATER.IF IRRIT OCCURS GET
MED ATTN. SKIN:REMOVE CONTAMIN CLOTH/SHOES.WIPE EXCESS OFF.FLUSH
W/WATER.FOLLOW BY WASHING W/SOAP & WATER.IF IRRIT OCCURS GET MED
ATTN. NOTE TO DR:IN GEN EMESIS INDUCTION UNNECESSARY IN HI VISC,LOW
VOLATI MATL

Fire Fighting

Flash Point Method:COC
Flash Point:400F,204C INGR#1
Extinguishing Media:USE WATER FOG,FOAM,CARBON DIOXIDE,DRY
CHEMICAL.DON'T USE DIRECT STREAM OF WATER.PRODUCT WILL FLOAT &
REIGNITE ON WATER.
Fire Fighting Procedures:MATL WILL NOT BURN UNLESS PREHEATED.COOL FIRE
EXPOSED CNTNRS W/WATER.DON'T ENTER CONFINED FIRE SPACE W/O FULL
BUNKER GEAR INCLUDING + PRESS NIOSH APPROVED SCBA.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:MAY BURN ALTHOUGH NOT READILY IGNI.WEAR
APPROPRIATE RESP & PROTECTIVE CLOTH.SHUT OFF LEAK W/O RISK.DIKE &
CONTAIN.REMOVE W/VACCUM TRUCKS/PUMP TO STORAGE/SALVAGE VESSELS.SOAK
UP RESIDUE W/ABSORBENT(CLA Y,SAND,SUITABLE MATL).FLUSH RESIDUE
W/WATER.
Neutralizing Agent:NOT APPLICABLE.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE WITH
ADEQUATE VENTILATION. KEEP AWAY FROM OPEN FLAMES & HIGH
TEMPERATURES.
Other Precautions:WASH W/SOAP & WATER BEFORE EATING, DRINKING, SMOKING,
APPLYING COSMETICS, OR USING TOILET FACILITIES. LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.

Exposure Controls

Respiratory Protection:USE A NIOSH-APPROVED RESPIRATOR AS REQUIRED TO
PREVENT OVEREXPOSURE. IN ACCORD W/29 CFR 1910.134 USE EITHER AN
ATMOSPHER-SUPPLYING RESPIRATOR OR AN AIR-PURIFYING RESPIRATOR FOR
ORGANIC VAPORS.
Ventilation:WORK IN A WELL VENTILATED AREA.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:SAFETY GLASSES OR GOGGLES.
Other Protective Equipment:WEAR OTHER CLOTHING AS REQUIRED TO MINIMIZE
CONTACT.
Work Hygienic Practices:AVOID CONTACT W/EYES. AVOID PROLONG/REPEAT
CONTACT W/SKIN.USE CAUTIOUS JUDGMENT WHEN CLEANING UP LARGE SPILLS.
Supplemental Safety and Health

Chemical Properties

HCC:V6
Spec Gravity:<1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID WITH MILD ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:AVOID HEAT AND OPEN FLAMES.
Hazardous Decomposition Products:COMPLEX MIX OF AIRBORNE
SOLIDS/LIQ/PARTICULATES/GASES WHEN PYRO;CO;OXIDES OF
ANTIMONY,SULFUR,LITHIUM,NITROGEN;ORG CMPDS.

Disposal

Waste Disposal Methods:PLACE IN APPROPRIATE DISPOSAL FACILITY IN
COMPLIANCE W/LOC REGS.UNDER EPA-CWA PRODUCT CONSIDERED AN OIL UNDER
SEC 313.SPILLS INTO/LEADING TO SURFACE WATERS THAT CAUSE SHEEN MUST
BE REPORTED TO NAT RES P CTR 800-424-8802.PER SARA CONTAINS
ANTIMONY CMPS

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their